APC RACK PDU 2G,METERED,ZEROU, 20A/208V (AP8858)
Actual product may differ
- 741719
- AP8858
- 96749177882
- APC
- Surge protection & line conditioners
- $2,016.81
- 5 available
Starting at
$1,408.54+GST
$1,619.82incl. GST
$1,525.00
$1,753.75
Save 8%
Pricing & availability
Sku
Name
Your price
Stock
APC METERED VERTICAL PDU, 230V, 16A, 3.3KW, C13(18), C19(2), IEC-320 C20, 2YR (AP8858) On sale!
5220581
$1,525.00
$1,753.75
$1,408.54
$1,619.82
Available
Overview
Metered Rack PDUFeatures & Benefits
Agility
-
Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
-
Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
-
Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Marketing Features
-
Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
-
Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
-
Local and web-based monitoringStatus available to customers both in the data center and remotely
-
Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
-
Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Availability
-
Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
-
Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
-
Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
-
Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
-
Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
-
Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Features
Specs
Display & graphics
Display depth
44 mm
Display height
902 mm
Display width
56 mm
Power, battery & charging
Input voltage
200 V, 208 V, 230 V, 230 V AC
Environment & regulatory
Eco friendly
Eco friendly
Packaging
What's in box
- Metered Rack AP8858 20-Outlets PDU
- Installation Guide
- Rack Mounting Brackets
- Safety Guide
- Sample Locking IEC Power Cord
- Serial Cable Configuration
Product info
Brand
APC by Schneider Electric
Product line
Metered Rack, NetShelter
Product name
Metered Rack AP8858 20-Outlets PDU
Product model
AP8858
Product series
Metered
Product type
PDU
Vendor
Schneider Electric SA
Vendor code
AP8858
Vendor site
Service & support
Warranty
2 year
Output
-
Nominal Output Voltage100V , 200V , 208V , 230V
-
Overload ProtectionNo
-
Maximum Total Current Draw16
-
Output Connections(18) IEC 320 C13 (Battery Backup)(2) IEC 320 C19 (Battery Backup)
Input
-
Nominal Input Voltage200V , 208V , 230V
-
Input frequency50/60 Hz
-
Input ConnectionsIEC-320 C20
-
Acceptable Input Voltage100-240VAC
-
Maximum Input Current20A
-
Regulatory Derated Input Current (North America)16A
Physical
-
Maximum Height902mm , 90.2CM
-
Maximum Width56mm , 5.6CM
-
Maximum Depth44mm , 4.4CM
-
Net Weight2.93KG
-
Shipping weight4.2KG
-
Shipping Height1124mm , 112.4CM
-
Shipping Width162mm , 16.2CM
-
Shipping Depth107mm , 10.7CM
-
ColorBlack
Environmental
-
Operating Temperature-5 - 45 °C
-
Operating Relative Humidity5 - 95 %
-
Operating Elevation0-3000meters
-
Storage Temperature-25 - 65 °C
-
Storage Relative Humidity5 - 95 %
-
Storage Elevation0-15000meters
Conformance
-
ApprovalsCSA C22.2 No. 60950, IEC 60950, METI Denan, UL 60950-1, VDE
-
Standard warranty2 years repair or replace
Sustainable Offer Status
-
RoHSCompliant
-
REACHREACH: Contains No SVHCs
-
Battery DirectiveCompliant
-
Battery Notests_Battery_Notes